RESTORE-USA Concrete & Masonry Sealer™ is a non-toxic, non-caustic, non-flammable inorganic formulation with no equal. It permanently waterproofs and preserves concrete and masonry with one easy application. Recommended application of one coat of RESTORE-USA Concrete & Masonry Sealer™ is 150-200 square feet / per gallon.

MASONRY- A LIFETIME BOND                

 The space between particles leaves untreated concrete or masonry subject to penetration by moisture, oils, acids, etc.

There are many types of foreign matter that is cancerous to concrete and masonry. Foreign matter is any acid, alkali or oil found in the concrete and masonry or found in such items as lactic acid in milk, oil, alkali, chemicals, etc. These cancerous substances imbed themselves in the masonry.

RESTORE-USA Concrete & Masonry Sealer™ applied to the masonry, concrete, plaster and stucco will penetrate and by a progressive chemical reaction, which is started at the surface, binds all component parts of the masonry into a more dense or solid mass. As this reaction takes place, all free lime and alkali are neutralized. As the masonry increases in density it becomes waterproofed, resistant to acid, oil and grease. RESTORE-USA Concrete & Masonry Sealer™ stops dusting, rutting, spading, prevents static. This process will stop cracking, crumbling, seepage and pitting while increasing the density of the masonry.  RESTORE-USA Concrete & Masonry Sealer™ also increases the tensile strength of the concrete as it fills all the voids preventing any penetration of water or contaminants from the surface either horizontally or vertically. In regards to the slab, RESTORE-USA Concrete & Masonry Sealer™ will not allow any vapor emission or water to come up from the ground.

According to U.S. Testing Laboratories, the interior of a piece of concrete contains a minimum or 361 times the amount of alkali as compared to the surface area. Therefore, RESTORE-USA Concrete & Masonry Sealer™, which uses the existing alkali to affect the cure, is 361 more times effective than any surface sealer and is also permanent. Anything applied only to the surface of the masonry must eventually come off due to aeration and deterioration. RESTORE-USA Concrete & Masonry Sealer™, which is locked into the interior, cannot deteriorate or wear off. Instead it cures, waterproofs and seals the masonry permanently.

After treating the masonry with RESTORE-USA Concrete & Masonry Sealer™ no foreign substance can penetrate into the masonry and will stay on the surface where it can be washed off easily. All masonry treated with RESTORE-USA Concrete & Masonry Sealer™ will stop disintegrating. You will no longer be able to remove a portion of the concrete, brick, and stucco etc. surface by running your finger across the surface based on the fact that component parts of the masonry are solidified into one mass, rather than a billion independent particles.

SECTION II - TYPICAL USES:

RESTORE-USA Concrete & Masonry Sealer™ is recommended for industrial, commercial and residential use on concrete, brick, stucco, paver stone, natural stone and all types of masonry. For homes, warehouses commercial buildings, factories, roads, tunnels, parking lot structures, hydroelectric dams, subways, basements and reservoirs. May be applied on interior or exterior surfaces of new or old masonry. Authorized by USDA for use in federally inspected meat packing plants and poultry houses.

SECTION III - TECHNICAL DATA:

  • APPEARANCE/ODOR : Slightly milky white/dries clear/no offensive odor
  • BOILING POINT : 110°C/230°F
  • EVAPORATION RATE : Same as water
  • FREEZING POINT : 0°C/32°F
  • PH (1-12) : 6.0
  • SPECIFIC GRAVITY : 1.10@ 20°C (Water=1)
  • % SOLID BY WEIGHT : 4.67%
  • SOLUBILITY IN WATER : Dilutable
  • STATE : Liquid
  • VOLATILE ORGANIC
  • COMPOUNDS : None
  • WEIGHT : 9.4 lb per gallon (10.00+/- .02)
  • SECTION IV - JOB LIMITATIONS:

Apply in good weather when air and surface temperature are above 45°F/7.22°C. Temperature must remain above 40°F/4.44°C for 24 hours after application. For optimum application properties, materials should be between 70-100°F/21.11-33.7°C prior to application. Maintain unmixed material in closed containers in protected storage at 40-100°F/4.44-33.7°C.

* DO NOT STORE IN STRONG SUNLIGHT, AS CONTAINER WILL EXPAND*

SECTION V - SURFACE APPLICATION:

Good surface preparation is essential to a satisfactory coating. Surfaces to be coated should be clean and dry. Remove all dirt, dust, oil, grease, mildew, rust and loose or cracked paint or other contamination by first cleaning the surface with RESTORE-USA Concrete & Masonry Cleaner™. Rinse thoroughly with water.

SECTION VI - APPLICATION PROCEDURE:

RESTORE-USA Concrete & Masonry Sealer™ should not be applied if temperature is 0°C/32°F or less. Applicator should always wear goggles and rubber gloves. In enclosed areas with no ventilation a dust mask would be recommended. Apply with pump sprayer or Flo-Jet pump 3.6 gallon per minute. When applied on vertical surfaces, back roll excess sealer. Theoretical coverage is approximately 150-200 square feet per gallon. Allow drying for 2 hours. Allow 5-7 days for completion of curing process and penetration after application. Prior to recoating allow 24-36 hours. Any coating may be applied over RESTORE-USA Concrete & Masonry Sealer™. Wash all tools and equipment with RESTORE-USA Concentrate Degreaser™ and water as soon as possible. Any spills may be cleaned with RESTORE-USA Concentrate Degreaser™ and water before it dries. We recommended not ponding product on the surface, even though it will dry clear, use 90° degree angles for maximum penetration to the cementatious matrix. Always test product before application to surfaces. All product information and application procedures are available on line at www.restore-usa.com.

SECTION VII – PRODUCT HANDLING INFORMATION:

PERSONAL PROTECTION: We recommend wearing rubber gloves and goggles which are available on our website  www.restore-usa.com.  If exposed to product during application or clean-up operations; see the emergency and first-aid procedures that follow.

SECTION VIII – HEALTH HAZARD DATA / EMERGENCY AND FIRST AID PROCEDURES:

  • EYE CONTACT : May cause irritation, redness and discomfort. Flush with water; eye drops recommended; always wear goggles.
  • SKIN CONTACT : Irritation, redness, itching and dryness. Rinse skin with soap and water when initially contacted.
  • INHALATION : May cause irritation in the respiratory system. Remove to fresh air; always ventilate enclosed areas.
  • INGESTION : May cause irritation and discomfort in the stomach. Provide several glasses of water to dilute; seek medical assistance.
  • EMERGENCY CONTACT : Contact your local physician or health care facility for further care.
  • SECTION IX - STORAGE AND HANDLING:
  • STORAGE CONDITIONS: Keep product from freezing 0°C/32°F. DO NOT STORE IN DIRECT SUNLIGHT FOR PROLONGED PERIODS OF TIME. Use caution as gasses may form in container and need to be released by opening cap on container. Average shelf life is approximately 12-15 month from date of product manufactured if maintained and stored properly.

SECTION X - PRODUCT DISCLAIMER:

The information contained herein about RESTORE-USA Concrete & Masonry Sealer™ is based on accurate and current data. However, no warranty is expressed or implied regarding the accuracy of this data or results to be obtained from the use thereof. Manufacturer/Vendor assumes no responsibility for injury to vendee, individual or third persons proximately caused by material if reasonable safety procedures are not adhered to as stipulated in the product data sheets. Additionally, Manufacturer/Vendor assumes no responsibility for injury to vendee, individual or third person proximately caused by abnormal use of the product even if reasonable safety procedures are followed. Furthermore, vendee, individual or third persons assumes the risk in the use of this product. RESTORE-USA dba Restoration Specialists, its officers or affiliated entities will not be liable for use of this product.